Manual
Analog Panel Meter  Instruction Manual 
19
Transmitter Supply Voltage Selection (P+, P-) 
All meters, including models equipped with the 12/24 VDC power 
option, are shipped from the factory configured to provide 24 VDC 
power for the transmitter or sensor. 
If the transmitter requires 5 or 10 VDC excitation, the internal jumper 
J4 must be configured accordingly. 
To access the voltage selection jumper: 
1.  Remove all the connectors. 
2. Unscrew the back cover. 
3.  Slide the back cover about 1 inch. 
4.  Configure the J4 jumper, located behind the input signal connector, 
for the desired excitation voltage as shown. 
Figure 5: Transmitter Supply Voltage Selection 
Connections 
All connections are made to removable screw terminal connectors 
located at the rear of the meter. 
Caution! 
Use copper wire with 60°C or 60/75°C insulation 
for all line voltage connections. Observe all 
safety regulations. Electrical wiring should be 
performed in accordance with all applicable 
national, state, and local codes to prevent 
damage to the meter and ensure personnel 
safety. 