User Manual
Series ACT Pneumatic and Electric Actuators
Specifications - Installation and Operating Instructions
Bulletin V-ACT
T
M
W.E. ANDERSON,
A DIV. OF DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360 U. S. A.
Phone: 219/879-8000 www.dwyer-inst.com
Fax: 219/872-9057 e-mail: info@dwyermail.com
T
he W.E. Anderson Series ACT
A
ctuators are available in either
p
neumatic or electric models. The wide
r
ange of torques and voltages means
there is an actuator for almost any
application. The standard ISO 5211
mounting configuration makes
i
nstallation to any valve or damper
q
uick and simple.
W
.E. Anderson pneumatic ACT models
are a compact rack-and-pinion design
with a symmetrical structure that
ensures fast and steady action, high
precision and high output power. The
c
orrosion resistant anodized aluminum
b
ody is designed to withstand the harsh
a
nd abusive industrial environments
and provide reliable service. We offer
double acting and spring return models
in a variety of sizes to fit any
application.
W
.E. Anderson electric ACT models are
a
vailable in two-position or modulating
c
onfigurations and NEMA 4X or NEMA
7
rated enclosures. All electric
actuators utilize a high grade powder
coated aluminum enclosure with visual
indicators. The two-position models
c
ome standard with two auxiliary
s
witches, and modulating models offer
a
n output for position monitoring.
C
ertain models are equipped with
manual overrides allowing the operator
to cycle the valve manually for
installation or maintenance checks.
SPECIFICATIONS
Pneumatic “DA” and “SR” Series
Type: DA series is double acting and
SR series is spring return (rack and
pinion).
Normal Supply Pressure:
DA: 40 to 115 psi (2.7 to 7.9 bar);
SR: 80 psi (5.5 bar).
Maximum Supply Pressure: 120 psi
(8.6 bar).
Air Connections:
DA01: 1/8˝ female NPT;
DA02 to DA5: 1/4˝ female NPT;
SR02 to SR07: 1/4˝ female NPT.
Housing Material: Anodized aluminum
body and epoxy coated aluminum
end caps.
Temperature Limits: -40 to 176°F (-40
to 80°C).
Accessory Mounting: NAMUR
standard.
Electric “TD” and “MD” Series
Power Requirements: 110 VAC,
220 VAC, 24 VAC or 24 VDC (MD
models not available in 24 VDC).
Power Consumption: See page 8.
Cycle Time (per 90°):
TD01 4 s;
MD01: 10 s;
TD02 and MD02: 20 s;
TD03 and MD03: 30 s.
Duty Rating: 85%.
Enclosure Rating: NEMA 4X (IP67).
Housing Material: Powder coated
aluminum.
Temperature Limits: -22 to 140°F
(-30 to 60°C).
Electrical Connection: 1/2˝ femle
NPT.
Modulating Input: 4 to 20 mA.
Standard Features: Manual override,
position indicator, and TD models
come with two limit switches.
Electric “TI” and “MI” Series
Power Requirements: 110 VAC,
220 VAC, 24 VAC or 24 VDC.
Power Consumption: See page 8.
Cycle Time (per 90°):
TI01 and MI01: 2.5 s;
TI02 and MI02: 5 s;
TI03 and MI03: 5 s;
TI04 and MI04: 10 s;
TI05 and MI06: 15 s.
Duty Rating:
Two-Position: TI01-TI06: 25%.
Modulating: MI01-MI06: 75%.
Enclosure Rating: NEMA 7.
Housing Material: Powder coated
aluminum.
Temperature Limits: -40 to 140°F
(-40 to 60°C).
Electrical Connection: 1/2˝ female
NPT.
Modulating Input: 4 to 20 mA.
Standard Features: Position indicator
and two limit switches.
ACT-TD01-110VAC
ACT-MI02-110VAC
A
CT-SR03