Relay action / Relay operation
You can configure the switching behavior of the relay output. Relay action can be specified either as open
switch (normally closed contact) or closed switch (normally open contact).
It is also possible to specify whether the output signal should be bistable or monostable. With bistable
operation, the relay remains in the activated state. With monostable operation, a delay time, after which the
relay reverts to its idle state, can be specified.
You can choose various events to activate output automatically. It is possible, for example, to switch a spotlight
on in response to a motion alarm and switch it off again when the alarm situation is no longer active.
Idle state:
Select Open if the relay is to operate as a normally open contact or Closed if it is to operate as a normally
closed contact.
Operating mode:
Select an operating mode for the relay.
If, for example, a light switched on by an alarm is to remain lit when the alarm has ended, select Bistable. If
an audible signal activated by an alarm is to sound for a period of ten seconds select Monostable with a 10
second delay time.
Relay follows:
Select an event to trigger the relay. The following events can activate the relay:
• Off
No relay triggering by events
• Connection
Triggering caused bby connection establishment
• Video alarm
Triggering caused by loss of the video signal
• Motion alarm
Triggering caused by the motion alarm
• Local input 1
Triggering caused by alarm input 1
• Remote input 1
Triggering caused by a relay contact at the target location (only when a connection is established)