User guide
4-48
CLIPSTER Edit Tool User Guide
After applying the recommended solution the problem should be re-
solved. However, if the drops persist, please contact the DVS service
department.
Throughout the
timeline
The storage location(s)
is(are) not real-time ca-
pable
Move the material to a real-time capa-
ble storage.
The storage location(s)
where the material is
stored is(are) too full
It is recommended to use only 85 %
of the overall storage capacity. If the
storage(s) is(are) too full, delete some
of the data.
Configurations of the
system have been al-
tered so that it is no
longer capable of real-
time operations
Contact the DVS service department.
One or more hard disks
of the storage array
may be damaged
Replace the defective disk(s) as de-
scribed in the hardware guide of the
DVS system.
If drops occur during a record operation with the DVS system,
one or more hard disks of the storage array may be damaged.
In this case replace the defective disk(s) as described in the
hardware guide.
Marker
Position
Timeline
Element
Probable Cause Solution