Port Name
Connection
Function
116
Alarm input port.
116
I/O port
Four groups of alarm input ports. The first
group is from port 1 to port 4, the second
group is from port 5 to port 8, the third
group is from 9 to 12, and the fourth group
is from 13 to 16. They are to receive the
signal from the external alarm source.
There are two types; NO (normal open)/NC
(normal close).
When your alarm input device is using
external power, please make sure the
device and the NVR have the same
ground.
Ground end
Alarm input ground end.
NO1NO5
Alarm output
port 15
5 groups of alarm output ports. (Group 1port
NO1C1,Group 2:port NO2C2,Group
3:port NO3C3.group 4: port NO4C4
Group 5port NO5C5NC5).Output alarm
signal to the alarm device. Please make sure
there is power to the external alarm device.
NONormal open alarm output port.
CAlarm output public end.
NC: Normal close alarm output port.
C1C5
NC5
A
RS485 port
RS485_A port. It is the cable A. You can
connect to the control devices such as speed
dome PTZ.
B
RS485_B.It is the cable B. You can connect to
the control devices such as speed dome PTZ.
CTRL 12V
Controllable 12V power output. It is to control
the on-off relay output. You can use it to enable
device alarm function.
It can also be used as the power input for some
alarm devices such as the smoke detector.
+12V
+12V power output port. It is to provide the
power to the peripheral devices such as camera
or alarm device. The connected device current
shall be less than 1A.