Owner manual
-17-
5.6.1 RS-232 and Telnet Command Set (continued)
Command Description
S SATURATION 0~60 Sets the numerical equivalent for the SATURATION setting (0~60).
R SATURATION Reports the numerical equivalent for the SATURATION setting.
S SHARPNESS 0~30 Sets the numerical equivalent for the SHARPNESS setting (0~60).
R SHARPNESS Reports the numerical equivalent for SHARPNESS setting.
S NR 0~3
0 = OFF 2 = MIDDLE
1 = LOW 3 = HIGH
R NR Reports the numerical equivalent for the NOISE REDUCTION setting (as above).
S VOLUME 0~100 Sets the numerical equivalent for VOLUME setting (0~100).
R VOLUME Reports the numerical equivalent for VOLUME setting.
S AUDIO DELAY 0~3
0 = OFF 2 = 110ms
1 = 40ms 3 = 150ms
R AUDIO DELAY Reports the numeric equivalent for the AUDIO DELAY setting (as above).
S AUDIO MUTE 0/1 0 = ON 1 = MUTE
R AUDIO MUTE Reports the numeric equivalent for the AUDIO MUTE setting (as above).
S HDMI AUDIO 0/1 0 = AUTO 1 = EXT
R HDMI AUDIO Reports the numeric equivalent for HDMI AUDIO setting (as above).
S KEY LOCK 0/1 0 = ENABLE 1 = DISABLE
R KEY LOCK Reports the numeric equivalent for KEY LOCK setting (as above).
S FREERUNCOLOR 0/1 0 = BLACK 1 = BLUE
R FREERUNCOLOR Reports the numerical equivalent for the free run color setting (as above).
S RESET 1 Resets the unit to factory defaults.
PORT 0~8
(1)
0 = LAST MEMORY 5 = VIDEO
1 = HDMI 1 6 = PC 1
2 = HDMI 2 7 = PC 2
3 = HDMI 3 8 = PC 3
4 = YPbPr
ST
Checks the FIRMWARE version and SOURCE information:
VERSION: 0.00 x.xx
SOURCE: HDMI ~ PC3
PORT ON: LAST ~ PC3
VOL + VOL - Raises or lowers the volume level from the current set volume.
QUIT Exit (Telnet Only).
Note 1: The “port” command sets the default input that will be selected when power is
applied to the unit. The “last memory” option makes the Switcher / Scaler unit power on
with whatever input was last viewed before powering off.