Specifications

Installer’s Guide – (Gas Post-Boost) Solar Water Heater
24
H4110 4110 Rev. F
Close the hot water outlet, then
repeat the above sequence to
conrm the setting.
Close the hot water outlet.


Setting the High Burner Rate
Set the Lower Dip Switch Block
(2) for maximum output setting as
shown right.
Open a hot water outlet fully in order
to start combustion.
Slowly rotate the maximum gas
control volume screw (4) clockwise or
anti-clockwise until the correct high
rate test point pressure is achieved.
Close the hot water outlet, then
repeat the above sequence to
conrm the setting.
Close the hot water outlet.
Return the Lower Dip Switch Block
(2) to the OFF position as shown
right.
Disconnect the manometer from the
test point and replace the blanking
screw.
Replace the front cover.
Installer’s Guide