Specifications

Installer’s Guide – (Gas Post-Boost) Solar Water Heater
20
H4110 4110 Rev. F


Connect the PTR valve and plumb
to waste to comply with AS/NZS
3500.4 and local plumbing codes.
The pipe from the PTR valve must:
be easily seen
pose no risk of damage to the
building or injury to persons.


Pipe sizes should be in accordance
with AS5601/AG601.
Fit a union to the water heater
gas inlet for easy connection and
removal. The thread diameter is
R¾"/20mm.
Fit an AGA approved isolating gas
cock in the supply line adjacent to
the water heater gas connection.
Ensure that the supply pipe and
the gas pressure regulator (LPG
or Natural Gas) has sufcient ow
capacity for this and other appliances
connected to the tting line.
For LPG appliances, ensure that
gas cylinders are of sufcient size.
The water heater alone will require a
regulator of 4kg per hour capacity.
PTR valve
Plumb to waste
to comply with
AS/NZS 3500.4
and local plumbing
codes
Gas inlet