Specifications

INSTALLATION CHECK LIST
1. Always transport the Airoheat in the upright position, if you lay it on its side
the refrigeration system may be compromised and the system may fail.
2. Avoid installing the unit near a bedroom window.
3. The Airoheat produces water condensation so make sure the unit is
installed on a flat surface and that a drain line is installed from the
condensation drain port so as to conduct the water to a suitable drainage
point.
4. Tempering Valves are a requirement, ensure they are commissioned
correctly; incorrect commissioning can lead to a lack of hot water delivery.
5. It is recommended that all hot water lines are insulated with high
temperature, UV resistant 13mm closed cell insulation.
6. Ensure there is no obstruction on top of the Airoheat that will block the air
outlet.
7. When the system is turned on, check the Hotlogic (inside top cover you can
access from top of Airoheat) status lights to help you determine operational
status.
8. Check the refrigerant sight glass disk located inside the top cover of the
unit, normal operation is indicated by a green indicator light. If the indicator is
yellow this indicates that you should not turn the unit on so in this instance
contact Dux Hot Water
9. Airoheat is designed for connection to a CONTINUOUS TARIFF, single
phase 240 volt AC supply
Part No: H3023 10 of 22
Version: 10155A