INSTALLER / CONSUMER SAFETY INFORMATION Please read this manual before installing and using appliance. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. —Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. —WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance.
Dutchwest Vent-Free Gas Heater Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation and Operating Instructions General Information.....................................................................
Dutchwest Vent-Free Gas Heater Installation & Operating Instructions In order to ensure safe and effective installation, this unit must be installed only by a qualified agency, individual, firm, corporation or company that is experienced in the installation, repair and servicing of this type of appliance and is familiar with the building codes and installation techniques appropriate in your area. Contact your hearth products dealer or local gas supplier for the name of a qualified service person.
Dutchwest Vent-Free Gas Heater Dutchwest Vent Free Gas Heater Dimensions Drawing Not to Scale 6���" (172mm) CL Valve Inlet 24���" (622mm) 28���" (721mm) C Valve 4���" L Inlet (111mm) 12���" (318mm) 23" (584mm) 17" (419mm) 2068 Fig. 1 Dutchwest dimensions.
Dutchwest Vent-Free Gas Heater Clearance Requirements A Minimum Clearances to Combustible Materials B Maintain clearance, (empty space), between combustible materials and the heater as specified below for the appropriate firebox shell being installed. C A E T D B D S U C V F W G X Y H Z ST101 A: B: C: D: Mantel/Trim* .......................... 35” (889mm) / 2” (51 mm) Side Wall/Trim*............................................. 2” (51 mm) ST101 Rear Wall ................................
Dutchwest Vent-Free Gas Heater High Elevations Gas Specifications Model 2475 2476 Fuel Nat Prop Gas Control Millivolt Millivolt Firebox weight / shipping Max. Input BTU/h 28,000 28,000 Min. Input BTU/h 19,500 19,500 110 lbs. Gas Inlet and Manifold Pressures Natural Inlet Minimum Inlet Maximum Manifold Pressure 5.5” w.c. 14” w.c. 3.5” w.c. LP (Propane) 11” w.c. 14” w.c. 10” w.c. (MP) 11” w.c. (RP) Dutchwest Vent-Free Certified to: ANSI Z21.11.
Dutchwest Vent-Free Gas Heater Vent Free Features The Dutchwest Vent Free, Model Nos. 2475 and 2476, are unvented gas heating appliances tested and listed to the ANSI Standard Z21.11.2a-2001. This appliance is specifically configured to burn either Natural Gas or Propane fuel, as indicated on the metal rating plate attached to the rear shroud. These stoves are not fuel convertible. The stove is shipped fully assembled and ready for installation.
Dutchwest Vent-Free Gas Heater Example: A room that is 18’ x 12’ x 8’ has a volume of 1728 cubic feet, ( length x width x height). An adjoining open kitchen that is 10’ x 12’ x 8’ has a volume of 960 cubic feet. An adjoining open dining room is 12’ x 12’ x 8’ with a volume of 1152 cubic feet. The total space volume is 3840 cubic feet. (1728 + 960 + 1152). 2. Divide the volume of space by 50 cubic feet. The result is the maximum BTU/Hr that the space can support. Example: 3840 divided by 50 = 76.
Dutchwest Vent-Free Gas Heater Assembly Procedures Install the Optional Fan 1. The fan kit includes a blower assembly and a rheostat assembly, connected by a cable. The blower assembly mounts to the bottom rear of the stove, and the rheostat mounts to the left side of the valve. The assembly includes a ‘snapstat’ which automatically turns the fan ON (or OFF) above (or below) approximately 109°F.
Dutchwest Vent-Free Gas Heater Outer Shroud Slot Inner Shroud Slot Rheostat ST194 Fig. 7 Position the fan to engage the inner shroud with the fan bracket slots and secure with sheet metal screws. Control Knob ST758 Fig. 9 Attach rheostat to left side of valve. ST758 Dutchwest attach rheostat 5/15/03 djt Snapstat MOTOR BLK BLK Left Air Duct ST194 attach fan to shroud 11/99 Retaining Nut BLK WHT Fig. 8 Install the snapstat and connect the extension wire terminals.
Dutchwest Vent-Free Gas Heater TH Thermostat Wire / Gauge 18 20 22 Maximum Run 40 feet 25 feet 16 feet TPTH TP 1. Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors. 2. Connect the thermostat wires to the valve. (Fig. 13) Connect the Gas Supply Line ST228 Fig. 12 Attach switch wires to valve.
Dutchwest Vent-Free Gas Heater CAUTION This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified below. The stove and its individual shutoff valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
Dutchwest Vent-Free Gas Heater Install the Stove Front Insert the handle stub into the hole in the front casting. Fasten in place with the 3/8” locking nut provided. (Fig. 16) Engage steel tabs behind the cast iron bosses The front attaches to the stove by four steel tabs that engage with corresponding cast ribs onto the sides and bottom of the stove body. Position the front about 3” down from stove top and lift the plate to engage the upper tabs behind the adjacent ribs on the sides. (Fig.
Dutchwest Vent-Free Gas Heater Your First Fire Read these instructions carefully and familiarize yourself with the burner controls shown on Page 16. Locate the pilot assembly, Figure 18. Follow the lighting instructions on Page 15 exactly. During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within the first eight to ten hours, however, you can open a window to provide fresh air to alleviate the condition.
Dutchwest Vent-Free Gas Heater Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater area for gas.
Dutchwest Vent-Free Gas Heater Troubleshooting Follow these procedures in the order presented. WARNING TURN OFF HEATER AND ALLOW TO COOL COMPLETELY BEFORE SERVICING. CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when Ignitor is operated. 1. Ignition Electrode is disconnected from ignition wire, broken or incorrectly positioned. 2. Ignitor wire is broken. 3. Bad Piezo Ignitor. 1. Inspect and re-connect, replace or repair as necessary. 1.
Dutchwest Vent-Free Gas Heater Troubleshooting cont’d. CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes out when Control Knob is released. 1. Control Knob not fully depressed or held in long enough. 2. Gas supply line shut-off valve is not fully open. 3. Thermocouple connection is loose at the Control Valve. 1. Depress Control Knob fully and hold in for a full 30 seconds. 4. Pilot flame does not touch the Thermocouple.
Dutchwest Vent-Free Gas Heater Maintenance The following procedures will help ensure that your heater continues to perform safely and efficiently. Screen Hooks Firebox Cleaning and Inspection Cleanliness is critical to correct operation of the heater. The log set, burner, valve controls and air circulation areas must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean whenever accumulation is evident. Follow the simple procedure outlined below.
Dutchwest Vent-Free Gas Heater 5 4 1a 7 8 1b 3 1d 1c 6 2 PILOT ADJ 15 ON 17 L I O H PI LO T OFF 11a,b 16 9a,b 12 13 10a,b 20 18a,b,c,d 14 21 19 25 22 24 23 28 27 29 26 2068 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Dutchwest Vent Free Gas Heaters Models 2475, 2476 Ref. 1. 1a. 1b. 1c. 1d. 2. 3. 4. 5.
Dutchwest Vent-Free Gas Heater Dutchwest Vent Free Gas Heaters Models 2475, 2476 (continued) Ref. 6. 7. 8. 9a. 9b. 10a. 10b. 11a. 11b. 12. 13. 14. 15. 16. 17. 18a. 18b. 18c. 18d. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. Description Leg, DW Gas End, Rt - DW Gas End, Lt - DW Gas Valve NG Honeywell - VS84212003 Valve LP Honeywell - VS84212011 Burner Housing Assy. - JUV NG Burner Housing Assy. - JUV LP Manifold Assy. - UVS27R Manifold Assy.
Dutchwest Vent-Free Gas Heater Optional Accessories Available Remote Controls Fan Kits FK28 Fan Assembly The FK28 fan kit helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature. A rheostat provides for variable fan speeds. Specifications The remote control allows you to turn the heater on or off from anywhere in the room.
Dutchwest Vent-Free Gas Heater 22 30002068
Dutchwest Vent-Free Gas Heater LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner. BASIC WARRANTY CFM Corporation Company (hereinafter referred to collectively as the Company) warrants that your new Dutchwest Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.