Specifications

3
Dutchwest
30003847
Specifications
A
C
B
D
G
F
E
1135
Dutchwest
specs
6/27/00 djt
Fig. 1 Dutchwest Convection Heater specifications.
Ref. 2460CE 2461CE 2462CE
A 560 mm (”) 654 mm (5³⁄₄”) 717 mm (8¹⁄₄”)
B 530 mm (1”) 60 mm (4¹⁄₂”) 690 mm (7”)
C 754 mm (9³⁄₄”) 760 mm (30”) 840 mm (33”)
D 410 mm (16”) 410 mm (16”) 467 mm (18¹⁄₄”)
E 375 mm (14³⁄₄”) 380 mm (14⁵⁄₈”) 430 mm (17”)
F 683 mm (6³⁄₄”) 690 mm (7”) 763 mm (30¹⁄₈”)
G 754 mm (9³⁄₄”) 760 mm (30”) 840 mm (33”)
460CE 461CE 46CE
Nominal heat output 8.0 kW (7,300 BTU/hr)
1
9.6 kW (3,400 BTU/hr)
1
11. kW (38,00 BTU/hr)
1
Minimum flue draught 1 Pa (0.048” WG) 1 Pa (0.048” WG) 1 Pa (0.048” WG)
Mean flue gas temp 39° C (64° F) 354° C (669° F) 354° C (669° F)
Efficiency (Space heating) 78.4% 76.% 76.%
Area heated 65-130 sq. m (700-1400 sq. ft.)
1
75-150 sq. m (800-1600 sq. ft.)
1
11-4 sq. m (100-400 sq. ft.)
1
Fuel Size/type 480 mm (19”) wood 560 mm (”) wood 640 mm (5”) wood
Flue mass gas flow 5.7 g/s 7.1 g/s 8.4 g/s
CO emissions
(@ 13% O
)
1700 ppm 300 ppm 300 pmm
Weight 17 kg (380 lbs.) 198 kg (436 lbs.) 88 kg (634 lbs.)
Width (leg-to-leg) 530 mm (1”) 60 mm (4¹⁄₂”) 690 mm (7”)
Depth (leg-to-leg) 375 mm (14³⁄₄”) 380 mm (14⁵⁄₈”) 430 mm (17”)
Height to top of flue collar 754 mm (9³⁄₄”) 760 mm (30”) 840 mm (33”)
Loading Side and front
Chimney connector 15 mm (6”) diameter
Chimney flue size 15 mm (6”) minimum
Flue exit position Reversible, top or rear
Air controls
Ash handling system Removable ash pan
Glass panels High temperature ceramic
1. This value can vary depending on how the stove is operated, the type and moisture content of the fuel used, as well as the design, construction
and climatic location of your home. Figures shown are based on nominal fuel consumption obtained under laboratory conditions and on average
efficiencies.