Customer Service Helpline 1.800.568.3949 dustlesstools.com
required. To determine ampere rating of
your vacuum, refer to nameplate located on
rear of motor cover. Before using appliance,
inspect power cord for loose or exposed
wires and damaged insulation. Make any
needed repairs or replacements before
using your appliance. Use only three-wire
outdoor extension cords which have three-
prong grounding-type plugs and three-pole
receptacles which accept the extension cords
plug. When vacuuming liquids, be sure the
extension cord connection does not come in
contact with the liquid.
NOTE: STATIC SHOCKS ARE COMMON IN DRY
AREAS OR WHEN THE RELATIVE HUMIDITY OF
THE AIR IS LOW. THIS IS ONLY TEMPORARY AND
DOES NOT AFFECT THE USE OF THE APPLI-
ANCE. TO REDUCE THE FREQUENCY OF STATIC
SHOCKS IN YOUR HOME, THE BEST REMEDY IS
TO ADD MOISTURE TO THE AIR WITH CONSOLE
OR INSTALLED HUMIDIFIER.
VOLTS TOTAL LENGTH OF
EXTENSION CORD IN FEET
120V 25 50 100 150
Ampere Rating
More Not More
Than Than
AWG
0 - 6 18 16 16 14
6 - 10 18 16 14 12
10 - 12 16 16 14 12
12 - 16 14 12
Not
Recommended
MAINTENANCE
FILTER INSTALLATION
(REGULAR WET+DRY)
1. Place the inner lter (small white lter)
over the lter support cage and attach
with the 7” hose clamp. Tighten the
clamp with a screw driver.
2. Place the shaker basket rod in the brass
hole. The basket should rest on top of the
lter.
3. Place the outer lter over the shaker
basket and around the raised lip on the lid
(lip is 1” from edge of the lid) attach with
the 10” hose clamp. Tighten the clamp
with a screw driver.
(HEPA WET+DRY)
1. Place the HEPA lter over the crosspiece
stud and slide on the washer. Screw on
the wing nut to compress the washer and
lter seal.