User Manual

7
Customer Service Helpline 1.800.568.3949 dustlesstools.com
CLEAN FILTERS (REGULAR WET+DRY)
1. Always turn off the vacuum before cleaning
the lters.
2. Keep the lid closed on the barrel, do not
remove the lid.
3. Remove the black agitator rod cover from
the lid.
4. Lift the agitator rod slightly and rapidly
shake it from side to side ve times so the
basket hits the sides of the outer lter to
knock off the layer of dust. Note: Pushing
down may push the lter off.
5. Replace the black agitator rod cover to the
top of the lid.
USAGE
DRY PICKUP
1. Barrel should be emptied of any wet waste.
Filters must remain in place.
2. Connect hose and desired attachment.
3. As suction is reduced stop to clean or
replace lters. (Refer to Clean Filters or Filter
Installation)
4. After use or when barrel is full turn off
vacuum and disconnect from outlet.
5. Remove intermediate from barrel.
6. Empty barrel and/or remove WunderBag.
Note: To avoid back strain, do not lift a full
barrel/bag.
7. Empty barrel after each use to prevent any
type of combustion.
CLEAN FILTERS (HEPA WET+DRY)
1. Turn the vacuum off and wait 5 seconds
after motor comes to a stop. Repeat 5
times. This allows weight to expand lter
cover and release dust.
2. For increased effectiveness, move the
vacuum vigorously side to side and back
and forth while shut down. Plugging and
unplugging the hose while running may
also restore some suction.
3. THOROUGH FILTER COVER CLEANING
Hand or machine wash the lter cover. Let it
line dry. DO NOT PUT IN THE DRYER.
4. Filter covers may also be vacuumed off to
restore suction.
5. HEPA lter should be discarded, DO
NOT attempt to clean HEPA lter. Proper
installation and use of the Wunderbag
and lter cover will maximize the life of the
HEPA lter.