User's Manual
Table Of Contents
- 1.0 Absolute Maximum Ratings
- 2.0 Normal Operating Conditions
- 3.0 Electrical Specifications
- 4.0 Radio
- 5.0 Pinout
- 6.0 Mote Boot Up
- 7.0 Interfaces
- 7.1 Timestamps
- 7.2 Status
- 7.3 Serial Interface
- 7.3.1 Serial Handshake Protocol
- 7.3.2 Mote Command Data Types
- 7.3.3 Mote Commands
- 7.3.3.1 Command 0x80 Serial Payload Sent to Mote Serial
- 7.3.3.2 Command 0x81 Unacknowledged Serial Payload Received from Mote Serial
- 7.3.3.3 Command 0x82 Acknowledged Serial Payload Received from Mote Serial
- 7.3.3.4 Command 0x84 Time/State Packet
- 7.3.3.5 Commands 0x87 and 0x88 Set Parameter Request/Response
- 7.3.3.6 Commands 0x89 and 0x8A Get Parameter Request/Response
- 7.3.3.7 Command 0x8C Mote Information
- 7.3.3.8 Command 0x8D Reset Mote
- 7.3.4 Mote Get/Set Command Parameters
- 7.3.5 HDLC Packet Processing Examples
- 8.0 Packaging Description
- 9.0 Regulatory and Standards Compliance
- 10.0 Ordering Information
Ordering Information
26 DUST NETWORKS™ M2135-1/M2030-1 MOTE DATASHEET
CONFIDENTIAL
9.1.2 FCC-approved Antennae
The following antenna specifications shall be FCC approved for use with the M2135-1/M2030-1 mote.
9.1.3 OEM Labeling Requirements
The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. The outside of the final
product enclosure must have a label with the following (or similar) text specifying the FCC identifier. The FCC ID and
certification code must be in Latin letters and Arabic numbers and visible without magnification.
or
9.2 IC Compliance
The M2135-1/M2030-1 shall be certified for modular Industry Canada (IC) approval. The OEM is responsible for its product
to comply with IC ICES-003 and FCC Part 15, Sub. B – Unintentional Radiators. ICES-003 is equivalent to FCC Part 15
Sub.
B and Industry Canada accepts FCC test reports or CISPR 22 test reports for compliance with ICES-003.
9.3 Industrial Environment Operation
The M2135-1/M2030-1 is designed to meet the specifications of a harsh industrial environments which includes:
• Shock and Vibration—
The M2135-1/M2030-1 complies with high vibration pipeline testing, as specified in IEC 60770-1.
• Hazardous Locations—The M2135-1/M2030-1 design is consistent with operation in UL Class 1, Division 2 Hazardous
Locations.
• Temperature Extremes—The M2135-1/M2030-1 is designed for industrial storage and operational temperature range of
–40 °C to 85 °C.
10.0 Ordering Information
Product List:
M2135-1: SmartMesh-XT / Long-range 2.4 GHz Serial Mote
M2030-1: SmartMesh-XT / 2.4 GHz Serial Mote
Contact Information:
Dust Networks
30695 Huntwood Ave.
Hayward, CA 94544
Toll-Free Phone: 1 (866) 289-3878
Website: www.dustnetworks.com
Email: sales@dustnetworks.com
Table 3 FCC-approved Antenna Specifications for the M2135-1/M2030-1
Gain Pattern Type Frequency Connector
TBD Omni-directional TBD 2.4–2.4835 GHz MMCX
Contains transmitter module FCC ID: SJC-xxxxx-xxxx
Contains FCC ID: SJC-xxxxx-xxxx.
PRELMINARY
Waring to the OEM: The OEM is cautioned that any changes or modifications not expressly
approved by the party responsible for compliance (Dust Networks, Inc.) could void the OEM’s
authority to operate the equipment as pursuant to FCC Rule 15.21