User's Manual
Table Of Contents
- 1.0 Absolute Maximum Ratings
- 2.0 Normal Operating Conditions
- 3.0 Electrical Specifications
- 4.0 Radio
- 5.0 Pinout
- 6.0 Mote Boot Up
- 7.0 Interfaces
- 7.1 Timestamps
- 7.2 Status LED Signal
- 7.3 Serial Interface
- 7.3.1 Serial Handshake
- 7.3.2 Mote Command Data Types
- 7.3.3 Mote Commands
- 7.3.3.1 Command 0x80 Serial Payload Sent to Mote Serial
- 7.3.3.2 Command 0x81 Unacknowledged Serial Payload Received from Mote Serial
- 7.3.3.3 Command 0x82 Acknowledged Serial Payload Received from Mote Serial
- 7.3.3.4 Command 0x84 Time/State Packet
- 7.3.3.5 Commands 0x87 and 0x88 Set Parameter Request/Response
- 7.3.3.6 Commands 0x89 and 0x8A Get Parameter Request/Response
- 7.3.3.7 Command 0x8C Mote Information
- 7.3.3.8 Command 0x8D Reset Mote
- 7.3.4 Mote Get/Set Command Parameters
- 7.3.5 HDLC Packet Processing Examples
- 8.0 Packaging Description
- 9.0 Regulatory and Standards Compliance
- 10.0 Ordering Information
Ordering Information
M1310-1 MOTE DATASHEET DUST NETWORKS™ 25
CONFIDENTIAL
9.1.2 FCC-approved Antennae
The following are FCC-approved antenna specifications for the M1310-1.
9.1.3 OEM Labeling Requirements
The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. The outside of the final
product enclosure must have a label with the following (or similar) text specifying the FCC identifier. The FCC ID and
certification code must be in Latin letters and Arabic numbers and visible without magnification.
or
9.2 IC Compliance
9.2.1 IC Testing
The M1310-1 should be certified for modular Industry Canada (IC) RSS-210 approval. The OEM is responsible for its product
to comply with IC ICES-003 and FCC Part 15, Sub. B - Unintentional Radiators. ICES-003 is equivalent to FCC Part 15
Sub. B and Industry Canada accepts FCC test reports or CISPR 22 test reports for compliance with ICES-003.
9.2.2 IC-approved Antennae
The following are IC-approved antenna specifications for the M1310-1.
9.3 Industrial Environment Operation
The M1310-1 is designed to meet the specifications of a harsh industrial environments which includes:
• Shock and Vibration—The M1310-1 complies with high vibration pipeline testing, as specified in IEC 60770-1.
• Hazardous Locations—
The M1310-1 design is consistent with operation in UL Class 1 Division 1 and UL Class 1
Division 2 Hazardous Locations.
• Temperature Extremes—The M1310-1 is designed for industrial storage and operational temperature range of
–40 °C to +85 °C.
10.0 Ordering Information
Product List:
M1310-1: SmartMesh-XD / 900 MHz Serial Mote
Contact Information:
Dust Networks
30695 Huntwood Ave.
Hayward, CA 94544
Toll-Free Phone: 1 (866) 289-3878
Website: www.dustnetworks.com
Email: sales@dustnetworks.com
Table 43 FCC-approved Antenna Specifications for the M1310-1
Gain Pattern Polarization Frequency Connector
+6 dBi maximum Omni-directional Vertical 902-928 MHz MMCX
Contains transmitter module FCC ID: SJC-XXXX
Contains FCC ID: SJC-XXXX
Table 44 IC-approved Antenna Specifications for the M1310-1
Gain Pattern Polarization Frequency Connector
+6 dBi maximum Omni-directional Vertical 902-928 MHz MMCX
ADVANCED INFORMATION