User's Manual
Table Of Contents
- 1.0 Absolute Maximum Ratings
- 2.0 Normal Operating Conditions
- 3.0 Electrical Specifications
- 4.0 Radio
- 5.0 Pinout
- 6.0 Mote Boot Up
- 7.0 Interfaces
- 7.1 Status LED Signal
- 7.2 Discrete Input/Output (I/O)
- 7.3 Deep Sleep
- 7.4 Serial Interface
- 7.4.1 Serial Flow Control
- 7.4.2 Mote Command Data Types
- 7.4.3 Mote Commands
- 7.4.3.1 Command 0x80 Serial Payload Sent to Mote Serial
- 7.4.3.2 Command 0x81 Unacknowledged Serial Payload Received from Mote Serial
- 7.4.3.3 Command 0x82 Acknowledged Serial Payload Received from Mote Serial
- 7.4.3.4 Command 0x84 Time/State Packet
- 7.4.3.5 Commands 0x87 and 0x88 Set Parameter Request/Response
- 7.4.3.6 Commands 0x89 and 0x8A Get Parameter Request/Response
- 7.4.3.7 Command 0x8C Mote Information
- 7.4.3.8 Command 0x8D Reset Mote
- 7.4.4 Mote Get/Set Command Parameters
- 7.4.5 HDLC Packet Processing Examples
- 8.0 Packaging Description
- 9.0 Regulatory and Standards Compliance
- 10.0 Ordering Information
Regulatory and Standards Compliance
26 DUST NETWORKS™ M1030-2 MOTE DATASHEET
CONFIDENTIAL
9.1.2 FCC-approved Antennae
The following are FCC-approved antenna specifications for the M1030-2:
9.1.3 OEM Labeling Requirements
The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. The outside of the final
product enclosure must have a label with the following (or similar) text specifying the FCC identifier. The FCC ID and
certification code must be in Latin letters and Arabic numbers and visible without magnification.
or
9.2 IC Compliance
9.2.1 IC Testing
The M1030-2 is certified for modular Industry Canada (IC) RSS-210 approval. The OEM is responsible for its product to
comply with IC ICES-003 and FCC Part 15, Sub. B - Unintentional Radiators. The requirements of ICES-003 are equivalent to
FCC Part 15 Sub. B and Industry Canada accepts FCC test reports or CISPR 22 test reports for compliance with ICES-003.
9.2.2 IC-approved Antennae
The following are IC-approved antenna specifications for the M1030-2.
9.2.3 OEM Labeling Requirements
The Original Equipment Manufacturer (OEM) must ensure that IC labeling requirements are met. The outside of the final
product enclosure must have a label with the following (or similar) text specifying the IC identifier. The IC ID and certification
code must be in Latin letters and Arabic numbers and visible without magnification.
.
9.3 Industrial Environment Operation
The M1030-2 is designed to meet the specifications of a harsh industrial environments which includes:
• Shock and Vibration—The M1030-2 complies with high vibration pipeline testing, as specified in IEC 60770-1.
• Hazardous Locations—
The M1030-2 design is consistent with operation in UL Class 1 Division 1 and Division 2
Hazardous Locations.
• Temperature Extremes—The M1030-2 is designed for industrial storage and operational temperature range of
–40 °C to +85 °C.
Table 44 FCC-approved Antenna Specifications for the M1030-2
Gain Pattern Polarization Frequency Connector
+6 dBi maximum Omni-directional Vertical 902-928 MHz MMCX
Contains transmitter module FCC ID: SJC-M1030
Contains FCC ID: SJC-M1030
Table 45 IC-approved Antenna Specifications for the M1030-2
Gain Pattern Polarization Frequency Connector
+6 dBi maximum Omni-directional Vertical 902-928 MHz MMCX
Contains IC:5853A-M1030