Full Product Manual
10 
PREPARE FOR STARTING 
  Caution: The machine has drained lube oil when it is delivered 
from factory. Fill the crankcase with oil before starting. 
3.2 Inspection for the Diesel Generator 
3.2.1 When the oil pressure goes down below safe level, 
the system will automatically shut off the engine to avoid 
damaging while the ignition key is still in the ON position. 
The engine will not start until the oil is refilled to proper 
level. If the diesel engine is running with insufficient lube 
oil, the oil temperature will raise. It is dangerous if there is 
too much oil. This may cause lube oil to burn. It can then 
cause the revolution speed of the diesel engine to 
increase suddenly and result in abnormal running. For 
this purpose, it is necessary to check the lube oil level 
and the level should maintain between the low and high 
level. 
3.2.2 Turn off main switch and disconnect all load (For ex: 
lamp and switch of motor). Check for damaged parts, 
loose or missing nuts and bolts. If problems occur, please 
do not start the engine, and consult our dealer. 
Before starting the generator set, be sure to turn the main 
switch to the OFF position. If the switch is not at the OFF 
position, it can cause damage to the generator and seize 
up the start motor with load to start. 
  WARNING: The generator should be started 
without load. 
3.3 Bleed Air from the Fuel Line 
If the engine is having difficulty starting and the 
fuel and oil level are acceptable, the problem can 
usually be traced to air bubbles trapped in the 
fuel line. The air should be discharged. 
The correct method is: 
 Turn the fuel cock beneath the fuel tank to the 
OFF position. Disconnect the fuel distributing 
pipe from high pressure pump. Turn the valve to 
the ON position and allow fuel to drip from the 
fuel line to a small container. Reattach the fuel 
line to the fuel pump when no air bubbles appear. 
3.4 Before starting the generator, make sure 
you have done the following: 
a. The generator is positioned on a firm level 
surface. 
b. The generator has been grounded. 
c. Check the lube oil level. 
d. Any spilled fuel has been wiped off. 
e. The ventilation is good. 
4 Start Generator Set 
4.1 Recoil Start 
 For the detailed start steps, please refer to 
the operation diagram on the next page. 
NOTE: On a cold day when it is difficult to 
start the diesel engine, screw out the screw 
plug on the cover of the diesel engine and fill 
in 2 ml of lube oil. 
  CAUTION: When filling oil, the plug 
screw should be screwed tightly on the 
cover to prevent dust and moisture 
sucked into the cylinder and can cause 
accelerated wear of internal parts. 