Add gasoline
The fuel cap is located on top of the fuel tank. Fill the tank
with fresh unleaded gasoline 87 octane or higher. The tank
is full when you see fuel in the bottom of the fuel lter cup.
DO NOT overll the tank.
2.
Turn gas valve on
The gas valve is located above the recoil start on the
bottom of the fuel tank. Rotate the valve counterclockwise
to the vertical position to turn on the gas supply.
4.
Add oil
The oil ll cap is located on the lower engine block to the
right of the recoil start housing. Remove the oil ll cap and
ll with 20 oz of 10w30 oil.
1.
Turn breaker o
The breaker is located on the right side of the front power
panel. Flip the breaker down to prevent accidental load
when starting the generator.
3.
Close choke
The choke lever is located above the air lter to the left
of the recoil start. Slide the lever to the left to cut the air
supply and allow more gas into the engine to start.
5.