Operating Guide
CAUTION: Never place any type of storage cover on the generator while it is still 
hot.
When transporting your generator: 
 ● Empty the gas tank (see “Emptying the Gas Tank” in the “Maintenance” section). 
 ● Disconnect the spark plug. 
 ● Do not obstruct any ventilation openings & keep the generator in a cool dry area.
Storage and Transportation
47
Storage Period Storage Preparation
If you plan on starting 
the same day.
1.  Turn o the main breaker.
2.  Allow the unit to run 3 - 5 minutes.
3.  Turn o the key.
4.  Store.
If you plan on starting 
the unit again within 
30 days.
1.  Turn o the main breaker.
2.  Allow the unit to run 3 - 5 minutes.
3.  Turn o the fuel valve.
4.  Allow the unit to stall out.
5.  Turn o the key.
6.  Add fuel stabilizer to the gas remaining in the tank.
7.  Store.
If you do not plan to 
start the unit for 
longer than 30 days.
1.  Turn o the main breaker.
2.  Allow the unit to run 3 - 5 minutes.
3.  Turn o the fuel valve.
4.  Allow the unit to stall out.
5.  Turn o the key.
6.  Drain the fuel tank (See “Emptying the Gas Tank” in the “Maintenance” section)
7.  Drain the carburetor
a.  Remove the drain bolt from the carburetor.
b.  Drain the small amount of remaining fuel from the carburetor bowl.
8.  Oil the cylinder
a.  Remove the spark plug.
b.  Put 2 tbsp. of 10w30 motor oil directly into the spark plug hole
c.  Pull the recoil start one time.
d.  Replace the plug.
9.  Remove the battery and place on tender indoors.