SERVICING YOUR GENERATOR
This symbol on the battery means that this product must not be treated as h ous eh old waste.
NOTE:
An improperly disposed of battery can be harmful to the environment
and human health .
Always confirm lo cal regulations for battery disp osal.
Battery Charging
The battery is rated at 30 .0Ah (ampere hours). Charging current should equal 10% of the battery’s ampere hour rating.
1. Connec t the battery charger followi ng the manufacturer’s in structions.
2. Charge the battery.
3. Clean the outsid e of the battery and the battery compartment with a solution of baking soda and water.
Battery Installation
1. Install the battery into the generator.
2. Connect the battery pos itive (+) cable to the battery positive (+) terminal first, and tighten t he bolt secure ly.
3. Slide th e battery boot over the positive (+) cable and term inal.
4. Connect the battery n egative (-) cable to t he battery negati ve (-) terminal, and tig hten the bolt securely.
25