OPERATION
AC Applications
Before connecting an appliance or power cord to the generator:
Make sure that it is in good work ing order. Faulty ap plianc es or Power cords can create a potential for electrica l
shock.
If an ap plianc e begins to operate abnormally, becomes sluggish , or stops suddenly, turn it
off immedia tely. Disconnect t he appliance, an d determine whet her the p rob lem is the appliance or the rated
load capacity of the generator has been exceeded.
Make sure that the electrical rating of the tool or appliance does not exceed that of the generator. Never exceed
the maximum power rating of the generator. Power levels between rated and maximum may be used for no more
than 30 minutes.
NOTICE
Substantial overloading will open the circuit breaker. Exceeding the time limit for m aximum power operation or slightly
overloading th e generator may not switch the circuit breaker OFF, but will shor ten the service life of th e gen erator.
Limit operation requiring m aximum power to 30 minutes.
Maximum power i s:
14
60Hz 13 kVA
For co nti nu ou s operation (longer than 30 minu tes), do not exceed the rated
pow er. Ra ted pow er is:
60Hz 12 kVA