Changing / Inspecting the AVR
The AVR regulates power from the generator. If the generator is overheated or overloaded, the
AVR may be damaged and require replacement.
Remove rear cover
Remove AVR bolts
Disconnect AVR wire clip
Remove the 4 bolts of the rear cover then pull the cover o
the generator.
Remove the 2 bolts holding the AVR.
Disconnect the wire clip.
1.
2.
3.
TROUBLESHOOTING (CONTINUED)