Degree
Description
Error
Serious error
Turn off the control unit and correct the error.
Warning
Eliminate the condition that caused the warning and the control unit will continue to work normally.
Information
Press OK
You can continue to work; only emergency running properties may be available.
The messages are visualised via LED2. The coding is displayed via LED2
flashing every 0.5 seconds. The flashing sequence is then interrupted for two seconds and
repeated.
Degree
Code
Error or information description
Remedial measures
Warning
1
Travel stop
- Check the tilt sensor on the machine
Information
2
Low voltage warning (1st threshold)
(mains voltage < 180V AC)
- Check mains voltage
- Stabilise mains voltage
- Use generator
Warning
3
Pedal position is not in position 0
- When switching on the control unit, take foot off
pedal
Error
4
Pedal not connected
- Connect analogue pedal
Error
5
Sewing motor encoder plug (Sub-D,
9-pin) not connected.
- Insert the encoder lead into the control unit. Use the
correct interface.
Error
6
Motor stalls
- Eliminate sluggish movement in the sewing machine
Error
7
Sewing motor overload
- Eliminate sluggish movement in the sewing machine
Error
8
Sewing motor error
Sewing motor plug (AMP) is not
connected.
- Check the connection and if necessary plug in.
- Test sewing motor phases (R= 2.8 Ohm, high-
resistance compared with PE)
- Replace sewing motor
- Replace control unit
Error
9
Sewing motor insulation error
- Check motor phase and PE for low-resistance
connection
- Replace sewing motor
Error
10
High voltage error, mains voltage
>290V for some time
- Check mains voltage, if rated voltage exceeded
permanently - stabilise or use generator
Error
11
EEprom communication error
- Check the connection of the Mach ID
- Turn off the control unit, wait until LEDs are off,
restart
Information
12
No valid data on external EEprom
- Check the connection of the Mach ID
- Turn off the control unit, wait until LEDs are off,
restart
- Update software
Error
13
Low voltage failure (2nd threshold)
(mains voltage < 150V AC)
- Check mains voltage
- Stabilise mains voltage
- Use generator
Error
14
Sewing motor turning in the wrong
direction
- Replace encoder
- Check that the motor plug is in the correct place and
change if necessary