5.2 Power supply (mains connection)
Working on the electrical equipment (connection, maintenance, repairs) must only be done by or under the
supervision of a qualified electrician.
The DAC
eco
control unit is intended to be connected to an earthed alternating current network with a rated
voltage in the range of 180V - 260 V 50/60 Hz.
Before connecting the mains lead, make sure that the rated voltage is within the rated voltage range
specified on the DAC
eco
rating plate.
It must only be connected using a multi-pin plug with an earthing contact.
A fixed connection is not permitted. The following potentials must be connected:
Phase (L1 or L2 or L3)
Neutral cable (N)
Protective earth (PE)
The DAC basic control unit is suitable for connection to the following mains:
TN mains with a directly earthed point, with a protective earth (PE) that is connected to this point.
TT mains with a directly earthed point where the protective earth (PE) is not connected to this mains earthing
point
.
IT mains that is not directly earthed.
PE
N
L3
L2
L1
DAC
DAC
DAC
DAC
L1
L2
PE
DAC
L3