5.6.5 Automatic sequence
Fig. 16: Automatic sequence I
To run the automatic sequence:
1. Press the right foot pedal.
Sewing head is switched on, cutting head is switched on.
The turntable is switched on, if the cutting head and sewing head
are run on the switch. The turntable is turned counterclockwise.
2. The turntable activates switch S1 (1) for the insertion position.
The turntable is switched off.
The clamp in the insertion position is opened after a delay and can be fed.
Fig. 17: Automatic sequence II
Caution: Risk of injury!
Do not reach into the area of the turntable or
the sewing/cutting heads during the automatic
sequence.
WARNING
(1) - Switch S1
(2) - Looper
(3) - Rack
(4) - Magazine
(5) - Initiator S3
(6) - Initiator S4
ཱི
ཱ
ུ
ི
ཱུ