Operation Manual
Maintenance
76 Operating manual 969 - 00.0 - 08/2014
Water condensation will accumulate in the water separator of the
maintenance unit.
Fig. 41: Water level in the maintenance unit
Check water level:
1. Check the water level every day.
Important: Water condensation must not rise up to the filter
element (1).
Drain water as required:
1. Switch off the sewing machine at the main power switch.
2. Place the collection tray under the drain screw (3).
3. Remove the compressed air hose from the compressed air
supply.
4. Completely unscrew the drain screw (3)
5. Allow water to drain into the collection tray.
0
2
8
4
6
10
1
2
3
(1) - Filter element
(2) - Water separator
(3) - Drain screw
ATTENTION
Machine damage possible if there is too much water.
Too much water can result in damage to the machine.
Check the water level every day and drain the condensation
water if there is too much water in the water separator.