Operating manual 969 - 00.0 - 08/2014 75
6.3 Checking pneumatic system
Fig. 40: Pressure indicator on maintenance unit
Check pressure:
1. Check the pressure and pressure gage (2) every day.
Standard value: 6 bar
Important: The pressure must never deviate from the
standard value by more than 1 bar.
ATTENTION
Machine damage possible due to incorrect pressure.
Incorrect pressure can result in damage to the machine.
Check the pressure on a daily basis.
Have the pressure adjusted by qualified specialists if the
pressure deviates from the reference value.
0
2
8
4
6
10
1
2
(1) - Standard value: 6 bar
(2) - Pressure gage