Operation Manual
Setup
88 Operating Manual 967 version 00.0 - 11/2013
7.10Checking pneumatic system
7.10.1 Assembling maintenance unit
The pneumatic connection package is available for this,
Additional equipment, p. 9. It includes:
• System connection hose
(length: 5 m; diameter: 9 mm)
• Hose connectors and hose clamps
• Coupling socket and coupling plug
Correct setting
The pressure in the pneumatic system network is 8 - 10 bar.
Fig. 48: Assembling pneumatic system maintenance unit
1. Attach the maintenance unit (3) to the upper cross bar (1) of
the frame using the bracket, screws and clip.
2. Connect the machine hose (4) coming out of the upper section
to the maintenance unit (3) at top right.
3. Connect the system connection tube (2) to the pneumatic sys-
tem.
Machine damage possible due to incorrect pressure.
Incorrect pressure can result in damage to the machine.
Make sure that the system pressure is set to 8 - 10 bar before
mounting the pneumatic system.
ATTENTION
(1) – Cross bar
(2) – System connection hose
(3) – Maintenance unit
(4) – Machine hose
ཱ
ི
ཱི