Operation Manual
Maintenance
Operating Manual 967 version 00.0 - 11/2013 73
Water condensation will accumulate in the water separator of the
maintenance unit.
Fig. 39: Water level in the maintenance unit
Check water level:
1. Check the water level every day.
Important: Water condensation cannot rise up to the filter
element (1).
Drain water as required:
1. Press the power switch to turn off the sewing machine.
2. Place the collection tray under the drain screw (3).
3. Remove the compressed air hose from the compressed air
supply.
4. Unscrew the drain screw (3) completely.
5. Allow water to drain into the collection tray.
6. Re-tighten the drain screw (3).
7. Connect the compressed air hose to the compressed air
supply.
8. Press the power switch again to turn the sewing machine back
on.
0
2
8
4
6
10
1
2
3
(1) – Filter element
(2) – Water separator
(3) – Drain screw
Machine damage possible if there is too much water.
Too much water can result in damage to the machine.
Check the water level every day and drain the condensation
water if there is too much water in the water separator.
ATTENTION