Operation Manual
Maintenance
72 Operating Manual 967 version 00.0 - 11/2013
6.3 Checking pneumatic system
Fig. 38: Pressure indicator on maintenance unit
Check pressure:
1. Check the pressure every day on the pressure indicator (2).
Standard level: 6 bar.
Important: The pressure cannot deviate from the standard
pressure by more than 1 bar.
Machine damage possible due to incorrect pressure.
Incorrect pressure can result in damage to the machine.
Check the pressure on a daily basis.
Have the pressure reset by qualified
technicians if it deviates from the standard level.
ATTENTION
0
2
8
4
6
10
1
2
(1) – Standard level: 6 bar
(2) – Pressure indicator