Operation Manual

Maintenance
Operating Manual 967 version 00.0 - 11/2013 71
Required oil:
Only DA 10 or equivalent oil should be used for the machine, which
has the following properties:
Viscosity at 40° C: 10 mm²/s
Flash point: 150 °C
Machine damage possible due to incorrect oil.
Incorrect oil types can result in damage to the machine.
Only use oil specified in the operating manual.
ATTENTION
Risk of environmental damage from oil.
Oil is a pollutant and must not enter the sewage
system or the soil.
Carefully collect waste oil and dispose of the waste
oil and oil-contaminated machine parts in the legally
prescribed manner.
ENVIRONMENTAL PROTECTION