Operation Manual

Operation
Operating Manual 967 version 00.0 - 11/2013 47
Fig. 24: Setting presser foot pressure
To increase presser foot pressure:
1. Release counternut (2).
2. Turn regulator (1) to the right until the desired pressure is
reached.
3. If the pressure is insufficient even when the regulator is fully
tightened, use the auxiliary spring (3) provided in the machine
accessories.
4. Completely loosen regulator (1)
(1) – Adjusting wheel
(2) – Counternut
(3) – Auxiliary spring
+
Risk to injury to eyes.
Loosening the regulator too much can cause it
to unscrew and be shot off by the spring under-
neath.
Always loosen with the presser foot lowered (less
spring tension).
Loosen the screw with one hand, pressing down
with the other to prevent it from coming off.
WARNING