2355 Stroke position stepper motor overload
• Transport system not moving freely
• Obstacles to the transport motion
• Correct the cause of not moving
freely
• Remove obstacles/adjust the motion
2356 Stroke position stepper motor
overtemperature
• Transport system not moving freely
• Stepper motor defective
• Controller defective
• Correct the cause of not moving
freely
• Replace the stepper motor
• Replace the controller
Machine controller
3100 Machine control voltage
• Short-term mains voltage dropout • Check the mains voltage
3102 Machine voltage in sewing motor
intermediate circuit
• Short-term mains voltage dropout • Check the mains voltage
3103 Machine voltage in stepper motor
intermediate circuit
• Short-term mains voltage dropout • Check the mains voltage
3107 Machine temperature
• Ventilation openings closed
• Ventilation grill dirty
• Clean the ventilation grill
• Check the ventilation openings
3109 Safe Stop is switched on Switch off Safe Stop
3121 Compressed air is missing or
insufficient
Turn on the compressed air, stabilize
3123 Oil sensor active Topping up with oil
3210 Broken thread Re-thread the thread
3215 Bobbin empty (remaining thread
counter)
Insert a full bobbin
3220 Bobbin empty (remaining thread
counter)
Insert a full bobbin
3500 Error in calculating the contour data • Reload the contour data
• Check the contour data
3501 Target position of the XY clamps
outside the motion limits
Adjust the contour data
3502 Target position of the XY clamps within
the “forbidden areas”
Adjust the contour data
3721
3722
Internal error • Switch the machine off and on again
• Software update
• Notify DA Service
4201 Internal CF card defective • Switch the machine off and on again
• Retrofit/replace controller
5301 Program cannot be sewn Copy program to DAC
Error
code
Description Troubleshooting