Operation Manual

Operating the controller
Operating manual 911 - Version 00.0 - 06/2013
75
Call up the
test page
1. In the menu item Extras > Service > Multitest tap the Test
inputs
/ outputs option.
The
IO Test Page window is displayed.
Figure 50: Testing inputs and outputs
The input elements are listed and selected at the left side (1) and the
output elements at the right side (2).
Testing an
element
2. Use Select + or Select - to select the desired element in the
respective area.
The number of the element is displayed on the
Selected:
button.
3. Tap the
Selected: button.
4. Test the element using the
On/Off or Switchover buttons,
depending on the type of the input or output element.
(1) - Area for input elements (2) - Area for output elements
཰ཱ
Input elements
No. Meaning
S1 Lower right clamp
S2 Lower left clamp
S9 Needle thread monitor active
S10 Bobbin cover closed
S11 Upper housing latch closed
S13 Pedal forwards
S14 Pedal backwards
S16 Pressure monitor
S17 Fast stop
S100 Sewing motor reference
S101 X-axis reference
S102 Y-axis reference
S103 Z-axis reference