Operation Manual
Operating the controller
Operating manual 911 - Version 00.0 - 06/2013
69
Pedal mode
The following options are available:
Mode 1: The current position of the pedal is evaluated.
Mode 2 (Def.): The pedal must be returned to the home position after every
actuation before a new actuation is recognized.
Mode 3: The current position of the pedal is evaluated.
The quick.start mode is also enabled (
Section Insertion mode,
page 64).
The machine must be switched off and on in order to enable the quick-start
mode.
Hand sensor: In hand sensor mode one sensor is used only for controlling
the clamp motion (up and down). The other sensor is used for starting the
sewing process.
MP2 - Limit values
Symbol Meaning
Max. speed
(min. = 500 .. max. 2700; Def. 2700 rpm)
All sewing programs are limited to this maximum speed.
Max. run-empty speed
(min. = 10 .. max. 100; Def. 100%)
Limits all clamp movements between the seams to this value.
Transport start angle
(min. = 30 .. max. 350; Def. 210 degrees)
The clamp motion during the stitch starts at this angle of needle motion.
Transport phase
(min. = 30 .. max. 100; Def. 80%)
This parameter defines how the clamp is to be moved during the stitch.
(A value of 100% means that the desired clamp motion is distributed over
the entire stitch.)
Needle reversing position
(min. = 0 .. max. 359; Def. 0 degrees)
The needle is reversed at this angle in order to increase the clearance to
the clamp.
Edit time paths
This function is only for Dürkopp Adler Service personnel.
Symbol Meaning