Operation Manual

Operating the controller
Operating manual 911 - Version 00.0 - 06/2013
63
Overview of the individual program parameters
PP1 - Configuration
Symbol Meaning
Seam name
max. 20 characters
Minimum sewing foot stroke height
(min. = 1.0 .. max. = 10.0; Def. = 5.0 mm )
Sets this as the minimum value of the programmable sewing foot stroke
height so that only this value needs to be adjusted when sewing thicker
materials.
Adjust the thread tension
(min. = 10… max. = 200; Def. = 100%)
The thread tension profile for the entire contour is adjusted accordingly. A
value of 100% means that no adjustments are made.
Adjust the run-empty speed
(min. = 10… max. = 200; Def. = 100%)
The forwarding speeds are adjusted accordingly.
Clamp ID code
Barcode (ID code) of max. 10 characters for performing a safety check
before the start of sewing (the barcode reader additional equipment must
be activated)
Laser marking lights
Up to four laser marking lights for easier alignment of the sewing material
can be controlled (the additional equipment must be activated)
Needle reversing mode
The following options can be set:
Not active: The needle remains at the Stop position.
After the entire contour: After completing all seams in the contour the
needle is reversed to the value specified in the machine parameters.
After every seam (Def.): The needle is reversed after every seam.
Needle cooling
(On/Off)
Activates/deactivates the needle cooling.
Adjust sewing speed
(min. = 10… max. = 200; Def. = 100%)
The sewing speed is adjusted by the specified percent value.