Operation Manual
Operating
22
Operating manual 911 - Version 00.0 - 06/2013
5.2 Switching on Safe Stop
Figure 3: Switching on Safe Stop
Switching on Safe Stop
1. Press in the button (1).
Important: The switch button must latch into place.
The sewing unit is in the Safe Stop mode.
The sewing feet are moved to the lower position.
The lamp in the button lights up.
The area around the looper cover (2) is lit up.
Switch off Safe Stop
1. Press in the button (1) again.
Important: The switch button must latch out of place.
Risk of injury from sharp or moving parts.
The sewing unit must first be switched off or switched to a Safe
Stop before performing any maintenance or setup work.
When the Safe Stop is active, do not reach into the looper area
until this is lit up.
WARNING
(1) - Safe Stop switch (2) - Looper cover
ཱ