Figure 67: Connect the compressed air maintenance unit
Connect the compressed air maintenance unit
1. Attach the connecting hose (2) (order number 0797 003031) to the
compressed air supply using a ¼" hose coupling.
Setting the operating pressure
The operating pressure is 6 bar. This can be read on the pressure
display (3).
1. Pull the turning handle (1) up.
2. Set the operating pressure in such a way that the pressure indicator (3)
indicates 6 bar:
To increase the pressure:
Turn the rotary handle (1) clockwise.
To reduce the pressure:
Turn the rotary handle (1) counterclockwise.
3. Push down the turning handle (1).
10.9 Oil lubrication
Section 9.2 Oil lubrication, page 90.
(1) - Turning handle (2) - Connecting hose
(3) - Pressure indicator