Operation Manual
Maintenance
86 Operating Instructions 911-210 - 01.0 - 11/2015
7.3 Pneumatic system
7.3.1 Setting operating pressure
Correct setting
The operating pressure is 6 bar.
Check the pressure on the pressure indicator every day. The pressure
cannot deviate by more than 1 bar.
Abb. 62: Setting operating pressure
Setting steps
1. Pull the adjustment knob (1) up.
2. Turn the turning handle until the pressure indicator (2) indicates 6 bar:
• clockwise: to increase pressure
• counterclockwise: to reduce pressure
3. Push the adjustment knob (1) down.
7.3.2 Draining the water condensation
Water condensation may accumulate in the water separator of the pres-
sure controller.
NOTICE
Machine damage due to incorrect pressure.
Incorrect pressure can result in damage to the machine.
Make sure that the machine is only used when the operating
pressure is set correctly.
(1) - Adjustment knob (2) - Pressure indicator
②
①