Operation Manual
Settings via software
60 Operating Instructions 911-210 - 01.0 - 11/2015
PP5 - Needle thread monitor
(min. = 0..max. = 99: Def. 5)
Is only active if activated in the machine parameters.
(A higher value makes the needle monitor less sensitive.
99 = Needle thread monitor switched off in this program only.)
PP6 - Thread consumption
Symbol Meaning
Sewing material thickness (min. = 0.. max. = 20.0; Def. 0)
The thickness of the sewing material when pressed together.
Material consumption adjustment
(min. = -10.0 .. max. 10.0; Def. 0)
Correction to the calculated value.
PP7 - Offset
Symbol Meaning
X offset
(min. = -5.0… max. = 5.0; Def. = 0.0 mm )
Y offset
(min. = -5.0… max. = 5.0; Def. = 0.0 mm )
PP8 - Scaling.
Symbol Meaning
X scaling
(min. = 80… max. = 120; Def. = 100 %)
100 % corresponds to the original size.
Y scaling
(min. = 80… max. = 120; Def. = 100 %)
X scaling origin
(min. = -150.0… max. = 150.0; Def. = 0.0 mm )