Operation Manual

Settings via software
Operating Instructions 911-210 - 01.0 - 11/2015 45
5.9 Resetting the counter
Depending on the machine parameter settings the counter counts the
sewn programs or sequences up or down. You can use
Reset
Counter
button to reset the counter to the start value ( Section MP6
- Counters, page 66).
Reset
Counter
1. Tap the Reset Counter button on the main screen.
The counter is reset to the value defined in the machine parameters.
5.10 Creating a new seam program
New seam programs are created using a Teach-In procedure.
Individual seam paths with specific seam parameters are defined via the
operating terminal in order to do this.
Calling up
Teach-In
1. Tap the menu items File > New > Seam Program.
The Teach-In window appears.
Fig. 36: Teach-In
Defining the starting point
Select the
starting
point
2. Use the arrow keys (3) to move the cursor (2) to the desired starting
position.
3. Tap the
OK button after entering the password.
The desired starting point is adopted and marked with a green dot.
(1) - Display of the cursor position
(2) - Cursor
(3) - Arrow buttons
(4) - OK button: “Accept”
(5) - Save button
(6) - Delete button
(7) - Parameter button
(8) - Line selection button