Operation Manual

Settings via software
34 Operating Instructions 911-210 - 01.0 - 11/2015
Button for bobbin change (8):
This button is used to inform the system that a new bobbin has been in-
serted (e.g. after a color change). The looper thread capacity is displayed
next to this button.
Button for resetting the counter (7):
This button can be used for resetting the counter for the sewn programs
or sequences. The current counter value is displayed next to this button.
5.4 General operation of the software
5.4.1 Entering a password
Depending on the settings ( Changing the password options, p. 67) a
password is only required for accessing the technical menus or is required
every time the machine is started. The password entry screen is displayed
when a password is required.
Fig. 21: Entering a password
Enter
password
Enter password
1. Use the numeric buttons (2) to enter the password.
The default password on delivery is: 25483.
The password can be changed via the
Extras menu ( page 67).
You can delete incorrect entries via the
DEL button.
2. Tap the
OK button after entering the password.
The previously selected menu item opens.