Operation Manual

Troubleshooting
106 Operating Instructions 911-210 - 01.0 - 11/2015
10.2 Messages of the software
10.2.1 Information messages
Code Description Troubleshooting
8400 Control panel has no valid pro-
gram for the DAC
Load the current program into the con-
trol panel from a USB stick.
8401
8402
Control panel has no valid pro-
gram for the DAC
Load the current program into the con-
trol panel from a USB stick.
8403 Program in DAC is no longer cur-
rent.
Load the current program into the
DAC.
8404
8407
DAC update failed. Attempt the update again
Check cable connections
Replace the DAC
8408 Waiting for a DAC reset. Wait until the restart has been per-
formed
(Duration: a few seconds).
8411 DAC program check is active. Wait until the test has been performed
(Duration: a few seconds).
8414 DAC update succeeded.
8801
8805
8806
8890
8891
Error in test pins/signal process-
ing/event processing/
memory wrapper/
list functions
Internal error
Switch the machine off and on again
Software update
Notify DA Service
System
9000 Reference run active
9002 Upper part not locked Lock the upper part
9006 Quick-stop button is active Release the Quick-stop button
9016 Incorrect barcode ID Change the program
9100 The counter has not reached the
specified value.
Tap the OK button. The counter is
reset.