Operation Manual

Setup
100 Operating Instructions 911-210 - 01.0 - 11/2015
Fig. 72: Connect the compressed air maintenance unit
Connect the compressed air maintenance unit
1. Attach the connecting hose (2) to the compressed air supply using a
¼" hose coupling.
Setting the operating pressure
The operating pressure is 6 bar. This can be read on the pressure
display (3).
1. Pull the turning handle (1) up.
2. Set the operating pressure in such a way that the pressure indicator (3)
indicates 6 bar:
To increase the pressure:
Turn the rotary handle (1) clockwise.
To reduce the pressure:
Turn the rotary handle (1) counterclockwise.
3. Push down the turning handle (1).
8.9 Oil lubrication
7.2 Lubrication, p. 83.
(1) - Turning handle (2) - Connecting hose
(3) - Pressure indicator