Operation Manual

Error- Description Possible cause Troubleshooting
code
6551
-
6554
6651
-
6653
6751
-
6761
6952
Error
Machine head
position /
AD-Converter /
Processor error / Step
motor driver
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
7451
7453
7454
Communication Test
Interface
Internal error
Switch the sewing machine off
and on again
7452
7455
Communication Test
Interface
- Transmission failure
- Cable Test interface
faulty
- Internal error
- Switch off the source of
interference
- Check cable
- Switch the sewing machine off
and on again
7551
-
7555
7558
7559
Communication
Terminal interface
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
7556
7557
Communication
Terminal interface
- Transmission failure
- Cable Terminal interface
faulty
- Switch off the source of
interference
- Check cable
7700 Protocol: Max number
of repetition
- Transmission failure
- Cable Test interface
faulty
- Switch off the source of
interference
- Check cable
7701 Error Protocol Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
8151
8156
-
8159
Error IDMA - Failure
- Control faulty
- Switch the sewing machine off
and on again
- Replace control
8152
-
8154
8251
8255
Error IDMA / Booting
ADSP / Booting
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
8252
8257
8258
/
8253
8256
8254
Booting ADSP /
Booting XILINX /
Booting
Failure
- Switch the sewing machine off
and on again
8351 Error Testpins Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
Should an error occurs, the corresponding component can be checked
over the menu service/multi-test for its correct function.