Operation Manual

Error- Description Possible cause Troubleshooting
code
3301
3320
-
3322
3330
-
3332
3340
3341
3350
-
3351
3353
3360
3361
3400
3401
3403
Error control
procedure / Test
procedure / Step
motor test procedure /
Starting procedure /
Sewing procedure /
Winding procedure /
Adjusting aids
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
4301 Dongle missing No dongle plugged in
Connect the dongle to the control
4302 Dongle empty No data s aved on the
dongle
Save the data on the dongle
4304 Wrong dongle type The dongle has not the
proper format for the
wished function
- Use other dongle type
- Format dongle
4307 Wrong machine class The dongle data is not
formatted for the cl. 910
- Use other dongle type
- Format dongle
4311 Error Format-ID - Dongle not formatted
properly
Dongle faulty
- Format the dongle anew
- Use a new dongle
4312 Unknown dongle type - Dongle not formatted
properly
- Dongle faulty
- Format the dongle anew
- Use a new dongle
5101 NV-RAM empty Control is brand new, no
data found
Control is for another
class, incompatible data
Data will be reset to factory setting.
5104 Error NV-RAM
checksum
NV-SRAM faulty
Failure
- Check via Multitest, if necessary
replace the control
Switch the sewing machine off
and on again
Data will be reset to factory setting.
5301
5302
5303
5305
5306
5340
Data contour
administration
Internal error
Switch the sewing machine off
and on again
Eventually the sewing prog. is not
ok:
Reset the sewing prog. again.
Load the sewing prog. from the
dongle again.
5900 Error sequences
Invalid sequence
number
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
6151
-
6154
Error input/output Internal error
Switch the sewing machine off
and on again
6351
-
6354
Error I
2
C Control faulty - Check control
- Software update
- Contact the DA-Service staff
65