Operation Manual

Inputs
With this test function the input element to be tested is selected.
ATTENTION !
The input elements have been carefully set in the factory.
Setting and correcting must only be done by trained service s taff.
Caution: Risk of injury!
Do not reach into the machine when starting and finishing the input
test.
Start the test function with the OK”key.
Select the desired input element with the keys ñ ”or“ò ”.
The switching status of the input element is indicated.
Press the function key ESC for quitting the test function.
The menu Multitest is displayed.
Input element Function
9 Needle thread monitor
25 Reference switch sewing motor
26 Reference switch X-motor
27 Reference switch Y-motor
1
43