Operating instructions

Decommissioning
Operating instructions 906 - Version 00.0 - 05/2014
129
6. Loosen both setscrews (1) but do not remove them
(screwdriver width 5 mm).
7. Remove six threaded screws (2) (screwdriver width 10 mm)
and cover plate (3).
8. Remove the automatic stacker from the bracket, rotate 180°
(the protective bar is at the bottom) and carefully put aside.