Operating instructions
Error and information messages
Operating instructions 906 - Version 00.0 - 05/2014
121
2353 Stroke position stepper motor overvolt-
age
• Mains voltage too high • Checking the mains voltage
2355 Stroke position stepper motor overload
• Transport system not moving freely
• Obstacles to the transport motion
• Correct the cause of not moving
freely
• Remove obstacles/adjust the motion
2356 Stroke position stepper motor over-
temperature
• Transport system not moving freely
• Stepper motor defective
• Controller defective
• Correct the cause of not moving
freely
• Replace the stepper motor
• Replace the controller
Machine controller
3100 Machine control voltage
• Short-term mains voltage dropout • Check the mains voltage
3102 Machine voltage in sewing motor inter-
mediate circuit
• Short-term mains voltage dropout • Check the mains voltage
3103 Machine voltage in stepper motor
intermediate circuit
• Short-term mains voltage dropout • Check the mains voltage
3107 Machine temperature
• Ventilation openings closed
• Ventilation grill dirty
• Clean the ventilation grill
• Check the ventilation openings
3109 Safe Stop is switched on Switch off Safe Stop
3121 Compressed air is missing or insuffi-
cient
Turn on the compressed air, stabilize
3123 Oil sensor active Refilling oil
3210 Broken thread Re-thread the thread
3215 Bobbin empty (remaining thread
counter)
Insert a full bobbin
3220 Bobbin empty (remaining thread
counter)
Insert a full bobbin
3500 Error in calculating the contour data • Reload the contour data
• Check the contour data
3501 Target position of the XY clamps out-
side the motion limits
Adjust the contour data
3502 Target position of the XY clamps within
the "forbidden areas"
Adjust the contour data
3721
3722
Internal error • Switch the machine off and on again
• Software update
• Notify DA Service
Error
code
Description Remedy