Operating instructions

Error and information messages
Operating instructions 906 - Version 00.0 - 05/2014
121
2353 Stroke position stepper motor overvolt-
age
Mains voltage too high Checking the mains voltage
2355 Stroke position stepper motor overload
Transport system not moving freely
Obstacles to the transport motion
Correct the cause of not moving
freely
Remove obstacles/adjust the motion
2356 Stroke position stepper motor over-
temperature
Transport system not moving freely
Stepper motor defective
Controller defective
Correct the cause of not moving
freely
Replace the stepper motor
Replace the controller
Machine controller
3100 Machine control voltage
Short-term mains voltage dropout Check the mains voltage
3102 Machine voltage in sewing motor inter-
mediate circuit
Short-term mains voltage dropout Check the mains voltage
3103 Machine voltage in stepper motor
intermediate circuit
Short-term mains voltage dropout Check the mains voltage
3107 Machine temperature
Ventilation openings closed
Ventilation grill dirty
Clean the ventilation grill
Check the ventilation openings
3109 Safe Stop is switched on Switch off Safe Stop
3121 Compressed air is missing or insuffi-
cient
Turn on the compressed air, stabilize
3123 Oil sensor active Refilling oil
3210 Broken thread Re-thread the thread
3215 Bobbin empty (remaining thread
counter)
Insert a full bobbin
3220 Bobbin empty (remaining thread
counter)
Insert a full bobbin
3500 Error in calculating the contour data Reload the contour data
Check the contour data
3501 Target position of the XY clamps out-
side the motion limits
Adjust the contour data
3502 Target position of the XY clamps within
the "forbidden areas"
Adjust the contour data
3721
3722
Internal error Switch the machine off and on again
Software update
Notify DA Service
Error
code