Error
code
Description Remedy
Sewing motor
1051 Sewing motor timeout
Cable to sewing motor reference
switch defective
Reference switch defective
Upper part does not move freely or
has excessive belt tension
Replace the cable
Replace the reference switch
Check the freedom of movement
and belt tension of the upper part
1052 Excessive sewing motor current
Sewing motor cable defective
Sewing motor defective
Controller defective
Replace the sewing motor cable
Replace the sewing motor
Replace the controller
1053 Sewing motor mains voltage too high Check the mains voltage
1055 Sewing motor overload
Sewing motor blocked/not moving
freely
Sewing motor defective
Controller defective
Remove the blockage/cause of lack
of freedom of movement
Check the sewing motor
Check the controller
1056 Sewing motor overtemperature
Sewing motor not moving freely
Sewing motor defective
Controller defective
Remove the cause of the lack of
freedom of motion
Replace the sewing motor
Replace the controller
1058
1302
1342
1344
Sewing motor speed
Sewing motor defective
Sewing motor error
Controller not receiving pulses from
pulse encoder in motor
Sewing motor error
Internal error
Replace the sewing motor
Check the cable from the pulse
encoder in the motor to the control-
ler
Switch the machine off and on again
Software update
Stepper motors
2101 X-axis stepper motor referencing time-
out
Faulty reference switch setting
Cable to reference switch defective
Reference switch defective
Adjust reference switch
Replace the cable
Check reference switch
2102 X-axis stepper motor current error
Stepper motor blocked
Encoder cable not connected or
defective
Encoder defective
Remove the blockage
Check/replace the encoder cable
Replace the stepper motor
2152 X-axis stepper motor overcurrent Replace the stepper motor
Replace the controller